Share:
Peer-Reviewed Publication
Int J Cardiovasc Imaging2025;41(2):211-223.February 1, 2025Journal Article

Performance of respiratory gated 4D flow MRI with adaptive k-space reordering in healthy controls and aortic dissection: reproducibility and agreement with 2D phase contrast MRI.

Qingdi Wang1, Xiaojing Guo2, Emma Hornsey3, Lucy McKenna3, Leonid Churilov4,5, Mark Brooks3, George Matalanis6,7, Jason Chuen6,7, Eric Poon8, Daniel Staeb9, Ning Jin10, Andrew Ooi2, Ruth P Lim3,6,11
1Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia. qingdiw@student.unimelb.edu.au.
2Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia.
3Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia.
4Department of Medicine, Melbourne Medical School, Royal Melbourne Hospital, The University of Melbourne, Heidelberg, VIC, Australia.
5Melbourne Medical School, Melbourne Brain Centre at Royal Melbourne Hospital, The University of Melbourne, Parkville, VIC, Australia.
6Department of Surgery, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia.
7Department of Cardiac Surgery, Austin Hospital, Heidelberg, VIC, 3084, Australia.
8Department of Medicine, Melbourne Medical School, Faculty of Medicine, Dentistry and Health Sciences, St Vincent's Hospital, The University of Melbourne, Fitzroy, VIC, 3065, Australia.
9MR Research Collaborations, Siemens Healthcare Pty Limited, Melbourne, VIC, 3153, Australia.
10Cardiovascular MR Research & Development, Siemens Medical Solutions Inc, Cleveland, OH, 43210, USA.
11Department of Radiology, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia.

Abstract

A four-dimensional phase-contrast magnetic resonance imaging sequence with respiratory-controlled adaptive k-space reordering (ReCAR-4DPC) offers potential benefits of improved scan efficiency and motion robustness. The purpose of this study was to evaluate the reproducibility of flow measurement using this technique and to compare hemodynamic metrics obtained to two-dimensional phase contrast MRI…

Create a free account to keep reading

Free members get 10 full research views every month across publications, clinical trials, FDA clearances, adverse events, and NIH grants. No credit card required.

Want unlimited research access? See Pro plans

Data Accuracy Notice: Research intelligence on Health AI Central is aggregated from public sources (PubMed, ClinicalTrials.gov, FDA, NIH, CMS, and others) and refreshed nightly. Classifications and derived metrics are produced by automated methods described in our Methodology. We recommend verifying critical data points against the primary sources before making decisions.