The promise of artificial intelligence in breast cancer detection has generated hundreds of research papers claiming breakthrough accuracies exceeding 99%. But a comprehensive systematic review has uncovered a troubling reality: 94.2% of these studies cannot be independently verified because researchers failed to share their code or replication materials.

The investigation, published in Computer Methods and Programs in Biomedicine Update, examined 154 peer-reviewed studies from 2020 to 2025 that applied deep transfer learning to mammography classification. What researchers found goes beyond a simple transparency problem—it reveals systematic methodological flaws that artificially inflate performance metrics and threaten the clinical translation of AI-assisted breast cancer detection.

Validation Shortcuts Create Inflated Benchmarks

The review identified a pervasive pattern of validation bias that makes published results appear far more impressive than real-world performance would support. According to the analysis, 38.7% of studies demonstrated high risk of validation bias, while an identical 38.7% showed high risk of overfitting or data leakage.

The most significant culprit: image-level data splitting. Only 3.2% of studies implemented patient-level data partitioning, meaning approximately 97% used methods that can inadvertently train and test on images from the same patient. This seemingly technical detail has dramatic consequences. Studies using image-level splits reported accuracies of 87–100% with area under the curve (AUC) metrics reaching 0.999, while those implementing proper patient-level partitioning yielded more modest results of 85–97% accuracy with AUC between 0.84 and 0.96.

The performance gap widens further when models face external validation. Only 40% of studies conducted testing on independent multi-center cohorts, and those that did saw substantial degradation. Models trained on the CBIS-DDSM dataset, for instance, saw AUC metrics decline from 0.918 to 0.776 when tested on the INbreast dataset—a drop of 0.14 points that could translate to hundreds of missed cancers in clinical practice.

The Dataset Diversity Problem

Beyond validation issues, the review found that 60–70% of studies relied exclusively on the same legacy public repositories: CBIS-DDSM, INbreast, and the MIAS database. These datasets are remarkably small by modern AI standards—MIAS contains only 322 images, while INbreast comprises 410 mammograms from just 115 patients.

This concentration on limited, homogeneous datasets compounds the reproducibility crisis. When 34.8% of studies exhibited high risk due to inadequate dataset size or single-center data dependency, the resulting models learn patterns specific to particular scanners, demographics, and imaging protocols rather than generalizable features of breast cancer.

The architectural choices showed similar homogeneity, with ResNet variants appearing in 30–35% of studies and 80% leveraging ImageNet-pretrained backbones. While preprocessing techniques like CLAHE and median filtering contributed to reported accuracies as high as 99.99%, these optimizations often mask underlying model limitations.

Implications for Clinical Deployment

The findings carry urgent implications for healthcare systems evaluating AI mammography solutions. The review, conducted according to PRISMA guidelines, found that 63% of analyzed papers exhibited high or unclear risk of bias in at least one methodological domain—a concerning statistic given that breast cancer represented 2.3 million new cases and 685,000 deaths globally in 2020.

For clinicians and procurement teams, the message is clear: vendor claims based on single-center studies with image-level validation should be viewed with skepticism. The 2–15 percentage point inflation from improper validation methods could mean the difference between a clinically useful tool and one that introduces dangerous false confidence.

The 94.2% code unavailability rate represents more than an academic concern—it prevents independent verification of safety and effectiveness claims that directly impact patient care. As historical computer-aided detection systems plateaued at 75–85% accuracy, the field needs rigorous, reproducible evidence to demonstrate genuine advancement rather than methodological artifacts.

Sources

  1. Deep transfer learning for breast cancer classification in mammography: A systematic review — Computer Methods and Programs in Biomedicine Update
  2. Systematic Review Finds Reproducibility Gaps in Transfer Learning for — scienmag.com